Wholesale Dealers of Pca Syringe Pump - KL-702 Syringe Pump – KellyMed
Wholesale Dealers of Pca Syringe Pump - KL-702 Syringe Pump – KellyMed Detail:
FAQ
Q: Do you have CE mark for this product?
A: Yes.
Q: Dual channel syringe pump?
A: Yes, two channels which can be operated separately and simultaneously.
Q: Is the pump open system?
A: Yes, Universal syringe can be used with our Syringe Pump.
Q: It the pump available to have customized syringe?
A: Yes, we have two customized syringes.
Q: Does the pump save last infusion rate and VTBI even when the AC power is switched OFF?
A: Yes, it is memory function.
Specifications
Model | KL-702 |
Syringe Size | 10, 20, 30, 50/60 ml |
Applicable Syringe | Compatible with syringe of any standard |
VTBI | 0.1-10000 ml
<100 ml in 0.1 ml increments ≥100 ml in 1 ml increments |
Flow Rate | Syringe 10 ml: 0.1-420 ml/h
Syringe 20 ml: 0.1-650 ml/h Syringe 30 ml: 0.1-1000 ml/h Syringe 50/60 ml: 0.1-1600 ml/h <100 ml/h in 0.1 ml/h increments ≥100 ml/h in 1 ml/h increments |
Bolus Rate | Syringe 10 ml: 200-420 ml/h
Syringe 20 ml: 300-650 ml/h Syringe 30 ml: 500-1000 ml/h Syringe 50/60 ml: 800-1600 ml/h |
Anti-Bolus | Automatic |
Accuracy | ±2% (mechanical accuracy ≤1%) |
Infusion Mode | Flow rate: ml/min, ml/h
Time-based Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc. |
KVO Rate | 0.1-1 ml/h (in 0.1 ml/h increments) |
Alarms | Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby, pressure sensor error, syringe installation error, syringe drop off |
Additional Features | Real-time infused volume, automatic power switching, automatic syringe
identification, mute key, purge, bolus, anti-bolus, system memory, history log, key locker, separate channel alarm, power saving mode |
Drug Library | Available |
Occlusion Sensitivity | High, medium, low |
History Log | 50000 events |
Wireless Management | Optional |
Power Supply, AC | 110/230 V (optional), 50/60 Hz, 20 VA |
Battery | 9.6±1.6 V, rechargeable |
Battery Life | Power saving mode at 5 ml/h,
10 hours for single channel, 7 hours for double channel |
Working Temperature | 5-40℃ |
Relative Humidity | 20-90% |
Atmospheric Pressure | 860-1060 hpa |
Size | 330*125*225 mm |
Weight | 4.5 kg |
Safety Classification | Class Ⅱ, type CF |
Product detail pictures:
Related Product Guide:
With responsible good quality method, good status and excellent client services, the series of solutions produced by our company are exported to lots of countries and regions for Wholesale Dealers of Pca Syringe Pump - KL-702 Syringe Pump – KellyMed , The product will supply to all over the world, such as: Sri Lanka, French, Czech republic, We integrate design, manufacture and export together with more than 100 skillful workers, strict quality controlling system and experienced technology.We keep long term business relationships with wholesaler and distributors form more than 50 countries, such as USA, UK, Canada, Europe and Africa etc.