Specifications
Model | KL-702 |
Syringe Size | 10, 20, 30, 50/60 ml |
Applicable Syringe | Compatible with syringe of any standard |
VTBI | 0.1-10000 ml
<100 ml in 0.1 ml increments ≥100 ml in 1 ml increments |
Flow Rate | Syringe 10 ml: 0.1-420 ml/h
Syringe 20 ml: 0.1-650 ml/h Syringe 30 ml: 0.1-1000 ml/h Syringe 50/60 ml: 0.1-1600 ml/h <100 ml/h in 0.1 ml/h increments ≥100 ml/h in 1 ml/h increments |
Bolus Rate | Syringe 10 ml: 200-420 ml/h
Syringe 20 ml: 300-650 ml/h Syringe 30 ml: 500-1000 ml/h Syringe 50/60 ml: 800-1600 ml/h |
Anti-Bolus | Automatic |
Accuracy | ±2% (mechanical accuracy ≤1%) |
Infusion Mode | Flow rate: ml/min, ml/h
Time-based Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc. |
KVO Rate | 0.1-1 ml/h (in 0.1 ml/h increments) |
Alarms | Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby, pressure sensor error, syringe installation error, syringe drop off |
Additional Features | Real-time infused volume, automatic power switching, automatic syringe
identification, mute key, purge, bolus, anti-bolus, system memory, history log, key locker, separate channel alarm, power saving mode |
Drug Library | Available |
Occlusion Sensitivity | High, medium, low |
History Log | 50000 events |
Wireless Management | Optional |
Power Supply, AC | 110/230 V (optional), 50/60 Hz, 20 VA |
Battery | 9.6±1.6 V, rechargeable |
Battery Life | Power saving mode at 5 ml/h,
10 hours for single channel, 7 hours for double channel |
Working Temperature | 5-40℃ |
Relative Humidity | 20-90% |
Atmospheric Pressure | 860-1060 hpa |
Size | 330*125*225 mm |
Weight | 4.5 kg |
Safety Classification | Class Ⅱ, type CF |
Product detail pictures:
Related Product Guide:
We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our administration ideal for Special Design for Syringe Pump Online - KL-702 Syringe Pump – KellyMed , The product will supply to all over the world, such as: French, Uzbekistan, Japan, So far our merchandise have been exported to east Europe, the Middle East, Southeast, Africa and South America etc. We have now 13years experienced sales and purchase in Isuzu parts at home and abroad and the ownership of the modernized electronic Isuzu parts checking systems. We honor our core principal of Honesty in business, priority in service and will do our best to provide our customers with high quality items and excellent service.