Short Lead Time for Mri Iv Pump - ZNB-XK Infusion Pump – KellyMed
Short Lead Time for Mri Iv Pump - ZNB-XK Infusion Pump – KellyMed Detail:
FAQ
Q: Do you have infusion mode of drop/min?
A: Yes.
Q: Does the pump have self-test facility?
A: Yes, it is automatically started when you switch on the pump.
Q: Does the pump have audible and visible alarms?
A: Yes, all the alarms are audible and visible.
Q: Does the pump save last bolus rate even when the AC power is switched OFF?
A: Yes, it is memory function.
Q: Does the pump have front panel lock-out mechanism to protect against incorrect operations?
A: Yes, it is key locker.
Specifications
Model | ZNB-XK |
Pumping Mechanism | Curvilinear peristaltic |
IV Set | Compatible with IV sets of any standard |
Flow Rate | 1-1300 ml/h (in 0.1 ml/h increments) |
Purge, Bolus | Purge when pump stops, bolus when pump starts, rate at 1100 ml/h |
Accuracy | ±3% |
*Inbuilt Thermostat | 30-45℃, adjustable |
VTBI | 1-9999 ml |
Infusion Mode | ml/h, drop/min, time-based |
KVO Rate | 1-5 ml/h (in 0.1 ml/h increments) |
Alarms | Occlusion, air-in-line, door open, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby |
Additional Features | Real-time infused volume, automatic power switching,
mute key, purge, bolus, system memory, key locker, nurse call |
Occlusion Sensitivity | 5 levels |
Air-in-line Detection | Ultrasonic detector |
Wireless Management | Optional |
Drop Sensor | Optional |
Nurse Call | Available |
Power Supply, AC | 110/230 V (optional), 50-60 Hz, 20 VA |
Battery | 9.6±1.6 V, rechargeable |
Battery Life | 6 hours at 30 ml/h |
Working Temperature | 10-40℃ |
Relative Humidity | 30-75% |
Atmospheric Pressure | 700-1060 hpa |
Size | 233*146*269 mm |
Weight | 3 kg |
Safety Classification | Class Ⅰ, type CF |
Product detail pictures:
Related Product Guide:
Our organization promises all customers with the first-class products and solutions and the most satisfying post-sale service. We warmly welcome our regular and new clients to join us for Short Lead Time for Mri Iv Pump - ZNB-XK Infusion Pump – KellyMed , The product will supply to all over the world, such as: Germany, Spain, Borussia Dortmund, Our factory covers an area of 12,000 square meters, and has a staff of 200 people, among which there are 5 technical executives. We are specialized in producing.We have rich experience in export. Welcome to contact us and your enquiry will be replied as soon as possible.
By Beryl from Kuwait - 2017.06.16 18:23
The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
By Doris from Mauritius - 2017.08.18 18:38
Write your message here and send it to us