Specifications
Model | ZNB-XK |
Pumping Mechanism | Curvilinear peristaltic |
IV Set | Compatible with IV sets of any standard |
Flow Rate | 1-1300 ml/h (in 0.1 ml/h increments) |
Purge, Bolus | Purge when pump stops, bolus when pump starts, rate at 1100 ml/h |
Accuracy | ±3% |
*Inbuilt Thermostat | 30-45℃, adjustable |
VTBI | 1-9999 ml |
Infusion Mode | ml/h, drop/min, time-based |
KVO Rate | 1-5 ml/h (in 0.1 ml/h increments) |
Alarms | Occlusion, air-in-line, door open, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby |
Additional Features | Real-time infused volume, automatic power switching,
mute key, purge, bolus, system memory, key locker, nurse call |
Occlusion Sensitivity | 5 levels |
Air-in-line Detection | Ultrasonic detector |
Wireless Management | Optional |
Drop Sensor | Optional |
Nurse Call | Available |
Power Supply, AC | 110/230 V (optional), 50-60 Hz, 20 VA |
Battery | 9.6±1.6 V, rechargeable |
Battery Life | 6 hours at 30 ml/h |
Working Temperature | 10-40℃ |
Relative Humidity | 30-75% |
Atmospheric Pressure | 700-1060 hpa |
Size | 233*146*269 mm |
Weight | 3 kg |
Safety Classification | Class Ⅰ, type CF |
Product detail pictures:
Related Product Guide:
Our firm since its inception, normally regards item top quality as company life, constantly make improvements to generation technology, improve product excellent and repeatedly strengthen organization total good quality management, in strict accordance with the national standard ISO 9001:2000 for Short Lead Time for Harga Infusion Pump - ZNB-XK Infusion Pump – KellyMed , The product will supply to all over the world, such as: British, Paris, Naples, We have been perfectly devoted to the design, R&D, manufacture, sale and service of hair products during 10 years of development. We have introduced and are making full use of internationally advanced technology and equipment, with advantages of skilled workers. "Dedicated to providing reliable customer service" is our aim. We are sincerely looking forward to establishing business relationships with friends from at home and abroad.