head_banner

KL-605T Syringe Pump

KL-605T Syringe Pump

Short Description:

Features:

1. Advanced mechanics for high infusion accuracy and consistency.

2. Anti-Siphonage design.

3. Comprehensive visible and audible alarms.

4. Applicable syringe size: 5, 10, 20, 30, 50/60 ml.

5. Customized syringe brand.

6. Automatic bolus reduction after occlusion.

7. Drug library with more than 60 drugs.

8. Wireless management: central monitoring by Infusion Management System.

9. DPS, the dynamic pressure system, detection of pressure variations in the Extension line.

10. Up to 8 hours battery backup, battery status indication.


Product Detail

Product Tags

FAQ

Q: Automatic recognition of syringe size and fixation

A: Yes.

Q: Syringe barrel clamp alarm?

A: Yes, it is Syringe Error alarm.

Q: Syringe plunger disengaged alarm?

A: Yes, it is Installation Error alarm.

Q: Automatic anti-bolus?

A: Yes, anti-bolus system to reduce pressure on sudden release of occlusion.

Q: Is it capable of horizontal stacking of more than two pumps?

A: Yes, it is stackable up to 4 pumps or 6 pumps.

 

Specifications

Model KL-605T
Syringe Size 5, 10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 1-1000 ml (in 0.1, 1, 10 ml increments)
Flow Rate Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)

Syringe 10 ml: 0.1-300 ml/h

Syringe 20 ml: 0.1-600 ml/h

Syringe 30 ml: 0.1-800 ml/h

Syringe 50/60 ml: 0.1-1200 ml/h

Bolus Rate Same as flow rate
Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy≤1%)
Infusion Mode Flow rate: ml/min, ml/h

Time-based

Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc.

KVO Rate 0.1-1 ml/h (in 0.01 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby,

pressure sensor error, syringe installation error, syringe drop off

Additional Features Real-time infused volume, automatic power switching,

automatic syringe identification, mute key, purge, bolus, anti-bolus,

system memory, history log, key locker

Drug Library Available
Occlusion Sensitivity High, medium, low
Docking Station Stackable up to 4-in-1 or 6-in-1 Docking Station with single power cord
History Log 50000 events
Wireless management Optional
Power Supply, AC 110/230 V, 50/60 Hz, 20 VA
Battery 14.8 V, rechargeable
Battery Life 8 hours at 5 ml/h
Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 700-1060 hpa
Size 245*120*115 mm
Weight 2.5 kg
Safety Classification Class Ⅱ, type BF

  • Previous:
  • Next:

  • Write your message here and send it to us