head_banner

KL-5021A Feeding Pump KellyMed

KL-5021A Feeding Pump KellyMed

Short Description:

Main feature

1. Palm size, portable.

2. Detachable charging base.

3. Up to 8 hours battery backup, battery status indication.

4. Withdraw and cleaning at adjustable rate.

5. Infusion warmer at adjustable temperature.

6. Compatible with vehicle power for ambulance.

7. Real-time display of VTBI / flow rate / infused volume.

8. DPS, the dynamic pressure system, detection of pressure variations in line.

9. On-site checking of history log up to 50000 events.

10. Wireless management: central monitoring by Infusion Management System.

11. Peristaltic model and easy to operate


Product Detail

Product Tags

The KL-5021A Feeding Pump by KellyMed is a high-quality medical device primarily used for nutritional support when patients are unable to ingest sufficient nutrition orally. Below is a detailed introduction to this product: I. Product Features Precise Control: The KL-5021A feeding pump employs advanced technology to precisely control infusion speed and dosage, ensuring patients receive appropriate nutritional support. Its flow rate ranges from 1mL/h to 2000mL/h, adjustable in increments or decrements of 1, 5, or 10mL/h, with a preset volume range of 1ml to 9999ml, similarly adjustable in increments or decrements of 1, 5, or 10ml, catering to the infusion needs of different patients. User-Friendly Operation: The product boasts a sleek and intuitive design, with easy-to-use controls and user-friendly features. The control panel's settings and monitoring functions allow healthcare providers to effortlessly perform various operations and adjustments. Stable and Reliable: The KL-5021A feeding pump offers stable performance and reliable quality, capable of running smoothly for extended periods, meeting the needs of long-term treatment. Its pump body is made of high-strength materials, with a compact structure for easy portability and installation. Versatile Functions: The feeding pump features adjustable aspiration and flushing functions, as well as rapid heating capabilities, ensuring patient safety and comfort. Additionally, it incorporates a peristaltic infusion function for higher precision, achieving accurate treatment. Strong Adaptability: The KL-5021A feeding pump comes with a vehicle power supply, suitable for various applications. Its high protection rating of IPX5 makes it adaptable to complex clinical environments. Furthermore, it features audible and visual alarms and wireless monitoring capabilities, compatible with infusion information collection systems. II. Application Scenarios The KL-5021A feeding pump is widely used in general wards, general surgery departments, intensive care units, and other departments of tertiary hospitals. It helps patients obtain necessary nutrients, improving their nutritional status and accelerating recovery. Additionally, this feeding pump can be used for infusing medications, blood products, and other fluids, possessing broad clinical application value. III. Usage Precautions Before using the KL-5021A feeding pump, healthcare providers should carefully read the product manual to ensure correct operation and usage. During infusion, healthcare providers should regularly monitor patients' nutritional status, adjusting infusion speed and dosage as needed. The use of feeding pumps requires strict adherence to operating procedures to ensure infusion safety and effectiveness. In case of equipment malfunctions or abnormalities, professional personnel should be promptly contacted for repairs and handling. In summary, the KL-5021A feeding pump by KellyMed is a fully functional, stable, and easy-to-operate medical device widely used in clinical nutritional support. It aids patients in obtaining necessary nutrients, enhancing treatment outcomes, and serving as an essential tool for healthcare providers.
Model KL-5021A
Pumping Mechanism Curvilinear peristaltic
Enteral Feeding Set Standard enteral feeding set with silicon tube
Flow Rate 1-2000 ml/h (in 1, 5, 10 ml/h increments)
Purge, Bolus Purge when pump stops, bolus when pump starts,adjustable rate at 600-2000 ml/h (in 1, 5, 10 ml/h increments)
Accuracy ±5%
VTBI 1-9999 ml (in 1, 5, 10 ml increments)
Feeding Mode ml/h
Suck 600-2000 ml/h (in 1, 5, 10 ml/h increments)
Cleaning 600-2000 ml/h (in 1, 5, 10 ml/h increments)
Alarms Occlusion, air-in-line, door open, end program, low battery,end battery, AC power off, motor malfunction,system malfunction, standby, tube dislocation
Additional Features Real-time infused volume, automatic power switching,mute key, purge, bolus, system memory, history log, key locker,withdraw, cleaning
*Fluid Warmer Optional (30-37℃, in 1℃ increments, over temperature alarm)
Occlusion Sensitivity High, medium, low
Air-in-line Detection Ultrasonic detector
Wireless Management Optional
History Log 30 days
Power Supply, AC 110-230 V, 50/60 Hz, 45 VA
Vehicle Power (Ambulance) 12 V
Battery 10.8 V, rechargeable
Battery Life 8 hours at 100 ml/h
Working Temperature 10-30℃
Relative Humidity 30-75%
Atmospheric Pressure 860-1060 hpa
Size 150(L)*120(W)*60(H) mm
Weight 1.5 kg
Safety Classification Class II, type CF
Fluid Ingress Protection IPX5

 

FAQ

Q: Are you the manufacturer of this product?

A: Yes, since 1994.

Q: Do you have CE mark for this product?

A: Yes.

Q: Is you company ISO certified?

A: Yes.

Q: How many years warranty for this product?

A: Two years warranty.

Q: Date of delivery?

A: Normally within 1-5 working days after payment received.

KL-5021A Feeding Pump (1)
KL-5021A Feeding Pump (2)
KL-5021A Feeding Pump (3)
KL-5021A Feeding Pump (4)
KL-5021A Feeding Pump (5)
KL-5021A Feeding Pump (6)
KL-5021A Feeding Pump (7)
KL-5021A Feeding Pump (8)
KL-5021A Feeding Pump (9)
KL-5021A Feeding Pump (10)
KL-5021A Feeding Pump (11)

  • Previous:
  • Next:

  • Write your message here and send it to us