1.Large LCD display for clear visibility.

2.Wide flow rate range from 0.01 to 9999.99 ml/h, adjustable in 0.01 ml increments.

3.Automatic KVO (Keep Vein Open) function with On/Off capability.

4.Real-time dynamic pressure monitoring for enhanced safety.

5.Eight working modes and twelve levels of occlusion sensitivity for versatile applications.

6.Compatibility with docking station for enhanced functionality.

7.Automatic multi-channel relay for efficient operation.

8.Multiple data transmission options for seamless connectivity.


Product Detail

Product Tags

KellyMed Syringe Pump KL-6061N workstation
,
1
2
3

Syringe Pump KL-6061N

Specifications

Syringe Size 5,10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
Flow Rate Syringe 5 ml: 0.1-100 ml/hSyringe 10 ml: 0.1-300 ml/hSyringe 20 ml: 0.1-600 ml/hSyringe 30 ml: 0.1-800 ml/hSyringe 50/60 ml: 0.1-1500 ml/h0.1-99.99 mL/h, in 0.01 ml/h increments

100-999.9 ml/h in 0.1 ml/h increments

1000-1500 ml/h in 1 ml/h increments

Flow Rate Accuracy ±2%
VTBI 0.10mL~99999.99mL (Minimum in 0.01 ml/h increments)
Accuracy ±2%
Time 00:00:01~99:59:59(h:m:s)  (Minimum in 1s increments)
Flow Rate  ( Body weight ) 0.01~9999.99 ml/h ;(in 0.01 ml increments)unit: ng/kg/min、ng/kg/h、ug/kg/min、ug/kg/h、mg/kg/min、mg/kg/h、IU/kg/min、IU/kg/h、EU/kg/min、EU/kg/h
Bolus Rate Syringe 5 ml: 50mL/h-100.0 mL/hSyringe 10 ml: 50mL/h-300.0 mL/hSyringe 20 ml: 50mL/h-600.0 mL/hSyringe 30 ml: 50mL/h-800.0 mL/hSyringe 50/60 ml: 50mL/h-1500.0 mL/h50-99.99 mL/h, in 0.01 ml/h increments

100-999.9 ml/h in 0.1 ml/h increments

1000-1500 ml/h in 1 ml/h increments

Accuray: ±2%

Bolus Volume Syringe 5 ml: 0.1mL-5.0 mLSyringe 10 ml: 0.1mL-10.0 mLSyringe 20 ml: 0.1mL-20.0 mLSyringe 30 ml: 0.1mL-30.0 mLSyringe 50/60 ml: 0.1mL-50.0 /60.0mLAccuracy: ±2% or ±0.2mL
Bolus , Purge Syringe 5mL :50mL/h -100.0 mL/hSyringe 10mL:50mL/h -300.0 mL/hSyringe 20mL:50 mL/h -600.0 mL/hSyringe 30mL:50 mL/h -800.0 mL/hSyringe 50mL:50 mL/h -1500.0 mL/h(Minimum in 1mL/h increments)

Accuracy: ±2%

Occlusion Sensitivity 20kPa-130kPa, adjustable (in 10 kPa increments)Accuracy: ±15 kPa or±15%
KVO Rate 1).Automatic KVO On/Off Function2).Automatic KVO is turned off : KVO Rate : 0.1~10.0 mL/h adjustable,(Minimum in 0.1mL/h increments).When flow rate>KVO rate , it runs in KVO rate.When flow rate <KVO rate , it alarms and runs in flow rate.3) Automatic KVO is turned on:it adjusts the flow rate automatically.When flow rate<10mL/h, KVO rate =1mL/h

When flow rate >10 mL/h, KVO=3 mL/h.

Accuracy: ±2%

Basic function Dynamic pressure monitoring, Anti-Bolus, Key Locker, Standby, Historical memory, Drug library.
Alarms Occlusion, syringe drop off, door open, near end , end program, low battery, end battery, motor malfunction, system malfunction, standby alarm, syringe installation error
Infusion Mode Rate mode, Time mode, Body weight, Sequence Mode、Dose Mode、Ramp Up/Down Mode、Micro-Infu Mode
Additional Features Self-checking, System Memory, Wireless (optional), Cascade, Battery Missing Prompt, AC Power Off Prompt.
Air-in-line Detection Ultrasonic detector
Power Supply, AC AC100V~240V 50/60Hz, 35 VA
Battery 14.4 V, 2200mAh ,Lithium, rechargeable
Weight of Battery 210g
Battery Life 10 hours at 5 ml/h
Working Temperature 5℃~40℃
Relative Humidity 15%~80%
Atmospheric Pressure 86KPa~106KPa
Size 290×84×175mm
Weight <2.5 kg
Safety Classification Class ⅠI, type CF. IPX3

5
8
7
9
11
10

FAQ:

Q:what’s the MOQ for this model ?

A: 1 unit.

Q: Is the OEM acceptable ? and what is the MOQ for OEM ?

A: Yes , We can do OEM based on 30 units .

Q: Are you the manufacture of this product.

A: Yes, since 1994

Q: Do you have CE and ISO certificates?

A: Yes . all our products are CE and ISO certified

Q: What is the warranty ?

A: We give two years warranty.

Q: Is this model workable with Docking station?

A: Yes

 

11
13Features :

➢ Compact design, lightweight, and small footprint for easy portability.
➢ User-friendly interface for simple and intuitive operation.
➢ Low operational noise for a quieter environment.
➢ Nine working modes to cater to various clinical needs.
➢ Pre-installed data for three syringe brands for convenient syringe selection.
➢ Customizable option to input data for two additional syringes.
➢ Anti-Bolus function to prevent over-infusion.
➢ Audio-visual alarms for enhanced patient safety.
➢ Simultaneous display of critical clinical data for at-a-glance monitoring.
➢ Automatic transition to KVO (Keep Vein Open) mode upon completion of VTBI infusion.

 