Infusion Pump
Infusion Pump,
Volumetric Infusion Pump,
FAQ
Q: Do you have CE mark for this product?
A: Yes.
Q: Type of infusion pump?
A: Volumetric infusion pump.
Q: Does the pump have pole clamp to be installed on an Infusion Stand?
A: Yes.
Q: Does the pump have alarm of infusion completion?
A: Yes, it is finish or end program alarm.
Q: Does the pump have inbuilt battery?
A: Yes, all of our pumps have inbuilt rechargeable battery.
Specifications
Model | ZNB-XD |
Pumping Mechanism | Curvilinear peristaltic |
IV Set | Compatible with IV sets of any standard |
Flow Rate | 1-1100 ml/h (in 1 ml/h increments) |
Purge, Bolus | Purge when pump stops, bolus when pump starts, rate at 700 ml/h |
Accuracy | ±3% |
*Inbuilt Thermostat | 30-45℃, adjustable |
VTBI | 1-9999 ml |
Infusion Mode | ml/h, drop/min |
KVO Rate | 4 ml/h |
Alarms | Occlusion, air-in-line, door open, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby |
Additional Features | Real-time infused volume, automatic power switching,
Mute key, purge, bolus, system memory |
Occlusion Sensitivity | 5 levels |
Air-in-line Detection | Ultrasonic detector |
Wireless Management | Optional |
Power Supply, AC | 110/230 V (optional), 50-60 Hz, 20 VA |
Battery | 9.6±1.6 V, rechargeable |
Battery Life | 5 hours at 30 ml/h |
Working Temperature | 10-40℃ |
Relative Humidity | 30-75% |
Atmospheric Pressure | 700-1060 hpa |
Size | 174*126*215 mm |
Weight | 2.5 kg |
Safety Classification | Class Ⅰ, type CF |
Infusion Pump
ZNB-XD
Features:
1. Built-in thermostat: 30-45℃ adjustable.
This mechanism warms IV tubing to increase infusion accuracy.
This is a unique feature compare to other Infusion Pumps.
2. Launched in 1994, the first China-made Infusion Pump.
3. Anti-free-flow function to make infusion safer.
4. Simultaneously calibrated to 6 IV sets.
5. Five levels of occlusion sensitivity.
Specifications
Model ZNB-XD
Pumping Mechanism Curvilinear peristaltic
IV Set Compatible with IV sets of any standard
Flow Rate 1-1100 ml/h (in 1 ml/h increments)
Purge, Bolus Purge when pump stops, bolus when pump starts, rate at 700 ml/h
Accuracy ±3%
*Inbuilt Thermostat 30-45℃, adjustable
VTBI 1-9999 ml
Infusion Mode ml/h, drop/min
KVO Rate 4 ml/h
Alarms Occlusion, air-in-line, door open, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby
Additional Features Real-time infused volume, automatic power switching,
Mute key, purge, bolus, system memory
Occlusion Sensitivity 5 levels
Air-in-line Detection Ultrasonic detector
Wireless Management Optional
Power Supply, AC 110/230 V (optional), 50-60 Hz, 20 VA
Battery 9.6±1.6 V, rechargeable
Battery Life 5 hours at 30 ml/h
Working Temperature 10-40℃
Relative Humidity 30-75%
Atmospheric Pressure 700-1060 hpa
Size 174*126*215 mm
Weight 2.5 kg
Safety Classification Class Ⅰ, type CF