Features:

1. Built-in thermostat: 30-45adjustable.

This mechanism warms IV tubing to increase infusion accuracy.

This is a unique feature compare to other Infusion Pumps.

2. Advanced mechanics for high infusion accuracy and consistency.

3. Applicable for adult, Paediatrics and NICU (Neonatal).

4. Anti-free-flow function to make infusion safer.

5. Real-time display of infused volume / bolus rate / bolus volume / KVO rate.

6, Large LCD display. Visible on-screen 9 alarms.

7. Change flow rate without stopping the pump.

8. Twin CPU’s to make infusion process safer.

9. Up to 5 hours battery backup, battery status indication.

10. Easy to use operation philosophy.

11. Recommended model by worldwide medical staff.


Product Detail

Product Tags

Infusion Pump,
Infusion Pump,





FAQ

Q: Are you the manufacturer of this product?

A: Yes, since 1994.

Q: Do you have CE mark for this product?

A: Yes.

Q: Is you company ISO certified?

A: Yes.

Q: How many years warranty for this product?

A: Two years warranty.

Q: Date of delivery?

A: Normally within 1-5 working days after payment received.

 

Specifications

Model KL-8052N
Pumping Mechanism Curvilinear peristaltic
IV Set Compatible with IV sets of any standard
Flow Rate 0.1-1500 ml/h (in 0.1 ml/h increments)
Purge, Bolus 100-1500 ml/h (in 1 ml/h increments)

Purge when pump stops, bolus when pump starts

Bolus volume 1-20 ml (in 1 ml increments)
Accuracy ±3%
*Inbuilt Thermostat 30-45℃, adjustable
VTBI 1-9999 ml
Infusion Mode ml/h, drop/min, time-based
KVO Rate 0.1-5 ml/h (in 0.1 ml/h increments)
Alarms Occlusion, air-in-line, door open, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby

Additional Features Real-time infused volume / bolus rate / bolus volume / KVO rate,

automatic power switching, mute key, purge, bolus, system memory,

key locker, change flow rate without stopping the pump

Occlusion Sensitivity High, medium, low
Air-in-line Detection Ultrasonic detector
Wireless Management Optional
Power Supply, AC 110/230 V (optional), 50-60 Hz, 20 VA
Battery 9.6±1.6 V, rechargeable
Battery Life 5 hours at 30 ml/h
Working Temperature 10-40℃
Relative Humidity 30-75%
Atmospheric Pressure 700-1060 hpa
Size 174*126*215 mm
Weight 2.5 kg
Safety Classification Class Ⅰ, type CF


KL-8052N infusion pump (1)
KL-8052N infusion pump (2)
KL-8052N infusion pump (3)
KL-8052N infusion pump (4)
KL-8052N infusion pump (5)
KL-8052N infusion pump (6)
KL-8052N infusion pump (7)
Infusion Pump
KL-8052N

Specifications
Model KL-8052N
Pumping Mechanism Curvilinear peristaltic
IV Set Compatible with IV sets of any standard
Flow Rate 0.1-1500 ml/h (in 0.1 ml/h increments)
Purge, Bolus 100-1500 ml/h (in 1 ml/h increments)
Purge when pump stops, bolus when pump starts
Bolus volume 1-20 ml (in 1 ml increments)
Accuracy ±3%
*Inbuilt Thermostat 30-45℃, adjustable
VTBI 1-9999 ml
Infusion Mode ml/h, drop/min, time-based
KVO Rate 0.1-5 ml/h (in 0.1 ml/h increments)
Alarms Occlusion, air-in-line, door open, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby
Additional Features Real-time infused volume / bolus rate / bolus volume / KVO rate,
automatic power switching, mute key, purge, bolus, system memory,
key locker, change flow rate without stopping the pump
Occlusion Sensitivity High, medium, low
Air-in-line Detection Ultrasonic detector
Wireless Management Optional
Power Supply, AC 110/230 V (optional), 50-60 Hz, 20 VA
Battery 9.6±1.6 V, rechargeable
Battery Life 5 hours at 30 ml/h
Working Temperature 10-40℃
Relative Humidity 30-75%
Atmospheric Pressure 700-1060 hpa
Size 174*126*215 mm
Weight 2.5 kg
Safety Classification Class Ⅰ, type CF