Infusion Pump
Infusion Pump,
,
FAQ
Q: Are you the manufacturer of this product?
A: Yes, since 1994.
Q: Do you have CE mark for this product?
A: Yes.
Q: Is you company ISO certified?
A: Yes.
Q: How many years warranty for this product?
A: Two years warranty.
Q: Date of delivery?
A: Normally within 1-5 working days after payment received.
Specifications
Model | KL-8052N |
Pumping Mechanism | Curvilinear peristaltic |
IV Set | Compatible with IV sets of any standard |
Flow Rate | 0.1-1500 ml/h (in 0.1 ml/h increments) |
Purge, Bolus | 100-1500 ml/h (in 1 ml/h increments)
Purge when pump stops, bolus when pump starts |
Bolus volume | 1-20 ml (in 1 ml increments) |
Accuracy | ±3% |
*Inbuilt Thermostat | 30-45℃, adjustable |
VTBI | 1-9999 ml |
Infusion Mode | ml/h, drop/min, time-based |
KVO Rate | 0.1-5 ml/h (in 0.1 ml/h increments) |
Alarms | Occlusion, air-in-line, door open, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby |
Additional Features | Real-time infused volume / bolus rate / bolus volume / KVO rate,
automatic power switching, mute key, purge, bolus, system memory, key locker, change flow rate without stopping the pump |
Occlusion Sensitivity | High, medium, low |
Air-in-line Detection | Ultrasonic detector |
Wireless Management | Optional |
Power Supply, AC | 110/230 V (optional), 50-60 Hz, 20 VA |
Battery | 9.6±1.6 V, rechargeable |
Battery Life | 5 hours at 30 ml/h |
Working Temperature | 10-40℃ |
Relative Humidity | 30-75% |
Atmospheric Pressure | 700-1060 hpa |
Size | 174*126*215 mm |
Weight | 2.5 kg |
Safety Classification | Class Ⅰ, type CF |
Features:
1. Built-in thermostat: 30-45℃ adjustable.
This mechanism warms IV tubing to increase infusion accuracy.
This is a unique feature compare to other Infusion Pumps.
2. Applicable for adult, Paediatrics and NICU (Neonatal).
3. Anti-free-flow function to make infusion safer.
4. Real-time display of infused volume / bolus rate / bolus volume / KVO rate.
5, Visible on-screen 9 alarms.
6. Change flow rate without stopping the pump.
Model KL-8052N
Pumping Mechanism Curvilinear peristaltic
IV Set Compatible with IV sets of any standard
Flow Rate 0.1-1500 ml/h (in 0.1 ml/h increments)
Purge, Bolus 100-1500 ml/h (in 1 ml/h increments)
Purge when pump stops, bolus when pump starts
Bolus volume 1-20 ml (in 1 ml increments)
Accuracy ±3%
*Inbuilt Thermostat 30-45℃, adjustable
VTBI 1-9999 ml
Infusion Mode ml/h, drop/min, time-based
KVO Rate 0.1-5 ml/h (in 0.1 ml/h increments)
Alarms Occlusion, air-in-line, door open, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby
Additional Features Real-time infused volume / bolus rate / bolus volume / KVO rate,
automatic power switching, mute key, purge, bolus, system memory,
key locker, change flow rate without stopping the pump
Occlusion Sensitivity High, medium, low
Air-in-line Detection Ultrasonic detector
Wireless Management Optional
Power Supply, AC 110/230 V (optional), 50-60 Hz, 20 VA
Battery 9.6±1.6 V, rechargeable
Battery Life 5 hours at 30 ml/h
Working Temperature 10-40℃
Relative Humidity 30-75%
Atmospheric Pressure 700-1060 hpa
Size 174*126*215 mm
Weight 2.5 kg
Safety Classification Class Ⅰ, type CF