It adheres to the tenet "Honest, industrious, enterprising, innovative" to develop new products constantly. It regards customers, success as its own success. Let us develop prosperous future hand in hand for Alaris Iv Pump Cost, Nutrition Bag, Medsystem 3 Infusion Pump, We are also constantly looking to establish relationship with new suppliers to provide innovative and smart solution to our valued customers.
Good Quality Intermittent Pneumatic Compression Device - KL-605T TCI Pump – KellyMed Detail:

Specifications

Model KL-605T
Syringe Size 5, 10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 1-1000 ml (in 0.1, 1, 10 ml increments)
Flow Rate Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)

Syringe 10 ml: 0.1-300 ml/h

Syringe 20 ml: 0.1-600 ml/h

Syringe 30 ml: 0.1-800 ml/h

Syringe 50/60 ml: 0.1-1200 ml/h

Bolus Rate 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)

10 ml: 0.1-300 ml/h

20 ml: 0.1-600 ml/h

30 ml: 0.1-800 ml/h

50/60 ml: 0.1-1200 ml/h

Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy≤1%)
Infusion Mode 1. Easy mode

2. Flow rate

3. Time-based

4. Body weight

5. Plasma TCI

6. Effect TCI

KVO Rate 0.1-1 ml/h (in 0.01 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby,

pressure sensor error, syringe installation error, syringe drop off

Additional Features Real-time infused volume, automatic power switching,

automatic syringe identification, mute key, purge, bolus, anti-bolus,

system memory, history log

Drug Library Available
Occlusion Sensitivity High, medium, low
History Log 50000 events
Power Supply, AC 110-230 V, 50/60 Hz, 20 VA
Battery 14.8 V, rechargeable
Battery Life 8 hours at 5 ml/h
Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 700-1060 hpa
Size 245*120*115 mm
Weight 2.5 kg
Safety Classification Class Ⅱ, type BF

Product detail pictures:

Good Quality Intermittent Pneumatic Compression Device - KL-605T TCI Pump – KellyMed detail pictures


Related Product Guide:

Well-run equipment, professional sales team, and better after-sales services; We are also a unified big family, everyone stick to the company value "unification, dedication, tolerance" for Good Quality Intermittent Pneumatic Compression Device - KL-605T TCI Pump – KellyMed , The product will supply to all over the world, such as: Indonesia, Johor, Ottawa, With good quality, reasonable price and sincere service, we enjoy a good reputation. Products are exported to South America, Australia, Southeast Asia and so on. Warmly welcome customers at home and abroad to cooperate with us for the brilliant future.
  • The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Astrid from Mauritius - 2017.11.11 11:41
    The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
    5 Stars By Audrey from Afghanistan - 2017.08.15 12:36
    Write your message here and send it to us