head_banner

Featured

  • Factory wholesale Sentinel Enteral Feeding Pump - Dual Feeding Pump with Automatic Flush Function Enteral Nutrition Pump use in ICU KL-5051N – KellyMed

    Factory wholesale Sentinel Enteral Feeding Pump - Dual Feeding Pump with Automatic Flush Function Enteral Nutrition Pump use in ICU KL-5051N – KellyMed

    Specification for Rotary Dual Channel Enteral Feeding Pump with Automatic Flush Function Model KL-5051N Pumping Mechanism Rotary with automatic flush function Enteral Feeding Set Compatible with T-shaped enteral feeding set, double channel Flow Rate 1-2000 ml/h (in 0.1 ml/h increments) Suck/Flush Rate 100~2000ml/h(in 1 ml/h increments) Purge/Bolus Volume 1-100 ml (in 1 ml increments) Suck/Flush Rate 100-2000 ml/h (in 1 ml/h increments) Suck/Flush Volume 1-1000 ml (in 1 ml i...
  • Manufacturing Companies for Mini Syringe Pump - KL-605T Syringe Pump – KellyMed

    Manufacturing Companies for Mini Syringe Pump - KL-605T Syringe Pump – KellyMed

    FAQ Q: Automatic recognition of syringe size and fixation? A: Yes. Q: Syringe barrel clamp alarm? A: Yes, it is Syringe Error alarm. Q: Syringe plunger disengaged alarm? A: Yes, it is Installation Error alarm. Q: Automatic anti-bolus? A: Yes, anti-bolus system to reduce pressure on sudden release of occlusion. Q: Is it capable of horizontal stacking of more than two pumps? A: Yes, it is stackable up to 4 pumps or 6 pumps.   Specifications Model KL-605T Syringe Size 5, 10, 20, 30, 5...
  • Manufactur standard Feeding Pump Near Me - KL-5021A Feeding Pump – KellyMed

    Manufactur standard Feeding Pump Near Me - KL-5021A Feeding Pump – KellyMed

    Model KL-5021A Pumping Mechanism Curvilinear peristaltic Enteral Feeding Set Standard enteral feeding set with silicon tube Flow Rate 1-2000 ml/h (in 1, 5, 10 ml/h increments) Purge, Bolus Purge when pump stops, bolus when pump starts,adjustable rate at 600-2000 ml/h (in 1, 5, 10 ml/h increments) Accuracy ±5% VTBI 1-9999 ml (in 1, 5, 10 ml increments) Feeding Mode ml/h Suck 600-2000 ml/h (in 1, 5, 10 ml/h increments) Cleaning 600-2000 ml/h (in 1, 5, 10 ml/h increments) ...
  • Professional Design Alaris Cc Syringe Pump - KL-605T Syringe Pump – KellyMed

    Professional Design Alaris Cc Syringe Pump - KL-605T Syringe Pump – KellyMed

    FAQ Q: Automatic recognition of syringe size and fixation? A: Yes. Q: Syringe barrel clamp alarm? A: Yes, it is Syringe Error alarm. Q: Syringe plunger disengaged alarm? A: Yes, it is Installation Error alarm. Q: Automatic anti-bolus? A: Yes, anti-bolus system to reduce pressure on sudden release of occlusion. Q: Is it capable of horizontal stacking of more than two pumps? A: Yes, it is stackable up to 4 pumps or 6 pumps.   Specifications Model KL-605T Syringe Size 5, 10, 20, 30, 5...
  • Lowest Price for Mri Infusion Pump - ZNB-XAII Infusion Pump – KellyMed

    Lowest Price for Mri Infusion Pump - ZNB-XAII Infusion Pump – KellyMed

    FAQ Q: Is the pump open system? A: Yes, Universal IV set can be used with our Infusion Pump after calibration. Q: Does the pump compatible with Micro IV Set (1 ml=60 drops)? A: Yes, all of our pumps are compatible with IV Set of 15/20/60 dorps. Q: Is it a peristaltic pumping mechanism? A: Yes, curvilinear peristaltic. Q: What is the difference between PURGE and BOLUS function? A: Purge used to remove air in line before infusion. Bolus can be administered for infusion therapy during infusion. ...
  • Wholesale Sentinel Feeding Pump - Kangaroo Tube Feeding Pump Enteral Nutrition Feeding Pump Match Kangroo Consumables KL-5041N with Automatic Flush Function – KellyMed
  • Good Quality Vet Use Pump – Veterinary Use Infusion Pump KL-8071A For Vet Clinic – KellyMed

    Good Quality Vet Use Pump – Veterinary Use Infusion Pump KL-8071A For Vet Clinic – KellyMed

    Specification for Veterinary Use Infusion Pump KL-8071A For Vet Clinic Model KL-8071A Pumping Mechanism Curvilinear peristaltic IV Set Compatible with IV sets of any standard Flow Rate 0.1-1200 ml/h (in 0.1 ml/h increments) Purge, Bolus 100-1200ml/h (in 1 ml/h increments) Purge when pump stops, bolus when pump starts Accuracy ±3% VTBI 1-20000ml Infusion Mode ml/h, drop/min, time-based KVO Rate 0.1-5ml/h Alarms Occlusion, air-in-line, door open, end program, low battery, e...
  • High Quality for Kangaroo 324 Feeding Pump - Portable Enteral Feeding Pump Nutrition Infusion Pump KL-5031N – KellyMed

    High Quality for Kangaroo 324 Feeding Pump - Portable Enteral Feeding Pump Nutrition Infusion Pump KL-5031N – KellyMed

    Specification for Enteral Feeding Pump KL-5031N: Model KL-5031N Pumping Mechanism Rotary Enteral Feeding Set Standard enteral feeding set with silicon tube, one channel Flow Rate 1-2000 ml/h (in 0.1 ml/h increments) Suck/Flush Rate 100~2000ml/h(in 1 ml/h increments) Purge/Bolus Volume 1-100 ml (in 1 ml increments) Suck/Flush Rate 100-2000 ml/h (in 1 ml/h increments) Suck/Flush Volume 1-1000 ml (in 1 ml increments) Accuracy ±5% VTBI 1-20000 ml (in 0.1 ml increments) F...
  • Super Lowest Price Syringe Pump Machine - KL-702 Syringe Pump – KellyMed

    Super Lowest Price Syringe Pump Machine - KL-702 Syringe Pump – KellyMed

    FAQ Q: Do you have CE mark for this product? A: Yes. Q: Dual channel syringe pump? A: Yes, two channels which can be operated separately and simultaneously. Q: Is the pump open system? A: Yes, Universal syringe can be used with our Syringe Pump. Q: It the pump available to have customized syringe? A: Yes, we have two customized syringes. Q: Does the pump save last infusion rate and VTBI even when the AC power is switched OFF? A: Yes, it is memory function.   Specifications Model KL-70...
  • Chinese wholesale Single Channel Syringe Pump - KL-702 Syringe Pump – KellyMed

    Chinese wholesale Single Channel Syringe Pump - KL-702 Syringe Pump – KellyMed

    FAQ Q: Do you have CE mark for this product? A: Yes. Q: Dual channel syringe pump? A: Yes, two channels which can be operated separately and simultaneously. Q: Is the pump open system? A: Yes, Universal syringe can be used with our Syringe Pump. Q: It the pump available to have customized syringe? A: Yes, we have two customized syringes. Q: Does the pump save last infusion rate and VTBI even when the AC power is switched OFF? A: Yes, it is memory function.   Specifications Model KL-70...
  • Top Suppliers Automated Syringe Pump - KL-605T Syringe Pump – KellyMed

    Top Suppliers Automated Syringe Pump - KL-605T Syringe Pump – KellyMed

    FAQ Q: Automatic recognition of syringe size and fixation? A: Yes. Q: Syringe barrel clamp alarm? A: Yes, it is Syringe Error alarm. Q: Syringe plunger disengaged alarm? A: Yes, it is Installation Error alarm. Q: Automatic anti-bolus? A: Yes, anti-bolus system to reduce pressure on sudden release of occlusion. Q: Is it capable of horizontal stacking of more than two pumps? A: Yes, it is stackable up to 4 pumps or 6 pumps.   Specifications Model KL-605T Syringe Size 5, 10, 20, 30, 5...
  • China wholesale Intermittent Pneumatic Compression Devices - KL-605T TCI Pump – KellyMed

    China wholesale Intermittent Pneumatic Compression Devices - KL-605T TCI Pump – KellyMed

    Specifications Model KL-605T Syringe Size 5, 10, 20, 30, 50/60 ml Applicable Syringe Compatible with syringe of any standard VTBI 1-1000 ml (in 0.1, 1, 10 ml increments) Flow Rate Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments) Syringe 10 ml: 0.1-300 ml/h Syringe 20 ml: 0.1-600 ml/h Syringe 30 ml: 0.1-800 ml/h Syringe 50/60 ml: 0.1-1200 ml/h Bolus Rate 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments) 10 ml: 0.1-300 ml/h 20 ml: 0.1-600 ml/h 30 ml: 0.1-800 ...