Factory Supply Syringe Pump And Infusion Pump - KL-702 Syringe Pump – KellyMed
Factory Supply Syringe Pump And Infusion Pump - KL-702 Syringe Pump – KellyMed Detail:
FAQ
Q: Do you have CE mark for this product?
A: Yes.
Q: Dual channel syringe pump?
A: Yes, two channels which can be operated separately and simultaneously.
Q: Is the pump open system?
A: Yes, Universal syringe can be used with our Syringe Pump.
Q: It the pump available to have customized syringe?
A: Yes, we have two customized syringes.
Q: Does the pump save last infusion rate and VTBI even when the AC power is switched OFF?
A: Yes, it is memory function.
Specifications
Model | KL-702 |
Syringe Size | 10, 20, 30, 50/60 ml |
Applicable Syringe | Compatible with syringe of any standard |
VTBI | 0.1-10000 ml
<100 ml in 0.1 ml increments ≥100 ml in 1 ml increments |
Flow Rate | Syringe 10 ml: 0.1-420 ml/h
Syringe 20 ml: 0.1-650 ml/h Syringe 30 ml: 0.1-1000 ml/h Syringe 50/60 ml: 0.1-1600 ml/h <100 ml/h in 0.1 ml/h increments ≥100 ml/h in 1 ml/h increments |
Bolus Rate | Syringe 10 ml: 200-420 ml/h
Syringe 20 ml: 300-650 ml/h Syringe 30 ml: 500-1000 ml/h Syringe 50/60 ml: 800-1600 ml/h |
Anti-Bolus | Automatic |
Accuracy | ±2% (mechanical accuracy ≤1%) |
Infusion Mode | Flow rate: ml/min, ml/h
Time-based Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc. |
KVO Rate | 0.1-1 ml/h (in 0.1 ml/h increments) |
Alarms | Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby, pressure sensor error, syringe installation error, syringe drop off |
Additional Features | Real-time infused volume, automatic power switching, automatic syringe
identification, mute key, purge, bolus, anti-bolus, system memory, history log, key locker, separate channel alarm, power saving mode |
Drug Library | Available |
Occlusion Sensitivity | High, medium, low |
History Log | 50000 events |
Wireless Management | Optional |
Power Supply, AC | 110/230 V (optional), 50/60 Hz, 20 VA |
Battery | 9.6±1.6 V, rechargeable |
Battery Life | Power saving mode at 5 ml/h,
10 hours for single channel, 7 hours for double channel |
Working Temperature | 5-40℃ |
Relative Humidity | 20-90% |
Atmospheric Pressure | 860-1060 hpa |
Size | 330*125*225 mm |
Weight | 4.5 kg |
Safety Classification | Class Ⅱ, type CF |
Product detail pictures:
Related Product Guide:
We constantly think and practice corresponding to the change of circumstance, and grow up. We aim at the achievement of a richer mind and body along with the living for Factory Supply Syringe Pump And Infusion Pump - KL-702 Syringe Pump – KellyMed , The product will supply to all over the world, such as: Egypt, Salt Lake City, Cologne, We will supply much better products with diversified designs and professional services. We sincerely welcome friends from over the world to visit our company and cooperate with us on the basis of long-term and mutual benefits.
By Elma from Nigeria - 2018.09.21 11:44
The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
By Annie from Bhutan - 2018.10.09 19:07