Factory Cheap Hot Dual Channel Syringe Pump - KL-605T Syringe Pump – KellyMed
Factory Cheap Hot Dual Channel Syringe Pump - KL-605T Syringe Pump – KellyMed Detail:
FAQ
Q: Automatic recognition of syringe size and fixation?
A: Yes.
Q: Syringe barrel clamp alarm?
A: Yes, it is Syringe Error alarm.
Q: Syringe plunger disengaged alarm?
A: Yes, it is Installation Error alarm.
Q: Automatic anti-bolus?
A: Yes, anti-bolus system to reduce pressure on sudden release of occlusion.
Q: Is it capable of horizontal stacking of more than two pumps?
A: Yes, it is stackable up to 4 pumps or 6 pumps.
Specifications
Model | KL-605T |
Syringe Size | 5, 10, 20, 30, 50/60 ml |
Applicable Syringe | Compatible with syringe of any standard |
VTBI | 1-1000 ml (in 0.1, 1, 10 ml increments) |
Flow Rate | Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)
Syringe 10 ml: 0.1-300 ml/h Syringe 20 ml: 0.1-600 ml/h Syringe 30 ml: 0.1-800 ml/h Syringe 50/60 ml: 0.1-1200 ml/h |
Bolus Rate | Same as flow rate |
Anti-Bolus | Automatic |
Accuracy | ±2% (mechanical accuracy≤1%) |
Infusion Mode | Flow rate: ml/min, ml/h
Time-based Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc. |
KVO Rate | 0.1-1 ml/h (in 0.01 ml/h increments) |
Alarms | Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby, pressure sensor error, syringe installation error, syringe drop off |
Additional Features | Real-time infused volume, automatic power switching,
automatic syringe identification, mute key, purge, bolus, anti-bolus, system memory, history log, key locker |
Drug Library | Available |
Occlusion Sensitivity | High, medium, low |
Docking Station | Stackable up to 4-in-1 or 6-in-1 Docking Station with single power cord |
History Log | 50000 events |
Wireless management | Optional |
Power Supply, AC | 110/230 V, 50/60 Hz, 20 VA |
Battery | 14.8 V, rechargeable |
Battery Life | 8 hours at 5 ml/h |
Working Temperature | 5-40℃ |
Relative Humidity | 20-90% |
Atmospheric Pressure | 700-1060 hpa |
Size | 245*120*115 mm |
Weight | 2.5 kg |
Safety Classification | Class Ⅱ, type BF |
Product detail pictures:
Related Product Guide:
As for aggressive rates, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such good quality at such charges we are the lowest around for Factory Cheap Hot Dual Channel Syringe Pump - KL-605T Syringe Pump – KellyMed , The product will supply to all over the world, such as: Bogota, Munich, Sri Lanka, With the intensified strength and more reliable credit, we are here to serve our customers by providing the highest quality and service, and we sincerely appreciate your support. We will endeavor to maintain our great reputation as the best products supplier in the world. If you have any questions or comments, please contact with us freely.
By Gill from Ecuador - 2018.02.08 16:45
In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
By Sandra from Barcelona - 2018.06.28 19:27