head_banner

Europe style for Excelsior Syringe Pump - KL-702 Syringe Pump – KellyMed

Europe style for Excelsior Syringe Pump - KL-702 Syringe Pump – KellyMed

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With state-of-the-art technologies and facilities, strict good quality regulate, reasonable cost, exceptional assistance and close co-operation with prospects, we're devoted to supplying the top benefit for our customers for Intermittent Pneumatic Compression Boots, Propofol Infusion Pump, Tci Infusion Pump, With a wide range, top quality, reasonable rates and stylish designs, our products are extensively used with this industries and other industries.
Europe style for Excelsior Syringe Pump - KL-702 Syringe Pump – KellyMed Detail:

FAQ

Q: Do you have CE mark for this product?

A: Yes.

Q: Dual channel syringe pump?

A: Yes, two channels which can be operated separately and simultaneously.

Q: Is the pump open system?

A: Yes, Universal syringe can be used with our Syringe Pump.

Q: It the pump available to have customized syringe?

A: Yes, we have two customized syringes.

Q: Does the pump save last infusion rate and VTBI even when the AC power is switched OFF?

A: Yes, it is memory function.

 

Specifications

Model KL-702
Syringe Size 10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 0.1-10000 ml

100 ml in 0.1 ml increments

100 ml in 1 ml increments

Flow Rate Syringe 10 ml: 0.1-420 ml/h

Syringe 20 ml: 0.1-650 ml/h

Syringe 30 ml: 0.1-1000 ml/h

Syringe 50/60 ml: 0.1-1600 ml/h

100 ml/h in 0.1 ml/h increments

100 ml/h in 1 ml/h increments

Bolus Rate Syringe 10 ml: 200-420 ml/h

Syringe 20 ml: 300-650 ml/h

Syringe 30 ml: 500-1000 ml/h

Syringe 50/60 ml: 800-1600 ml/h

Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy ≤1%)
Infusion Mode Flow rate: ml/min, ml/h

Time-based

Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc.

KVO Rate 0.1-1 ml/h (in 0.1 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby,

pressure sensor error, syringe installation error, syringe drop off

Additional Features Real-time infused volume, automatic power switching, automatic syringe

identification, mute key, purge, bolus, anti-bolus, system memory,

history log, key locker, separate channel alarm, power saving mode

Drug Library Available
Occlusion Sensitivity High, medium, low
History Log 50000 events
Wireless Management Optional
Power Supply, AC 110/230 V (optional), 50/60 Hz, 20 VA
Battery 9.6±1.6 V, rechargeable
Battery Life Power saving mode at 5 ml/h,

10 hours for single channel, 7 hours for double channel

Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 860-1060 hpa
Size 330*125*225 mm
Weight 4.5 kg
Safety Classification Class Ⅱ, type CF

Product detail pictures:

Europe style for Excelsior Syringe Pump - KL-702 Syringe Pump – KellyMed detail pictures


Related Product Guide:

Innovation, good quality and reliability are the core values of our enterprise. These principles today extra than ever form the basis of our success as an internationally active mid-size organization for Europe style for Excelsior Syringe Pump - KL-702 Syringe Pump – KellyMed , The product will supply to all over the world, such as: Monaco, Malaysia, Florida, Our company upholds the spirit of "innovation, harmony, team work and sharing, trails, pragmatic progress". Give us a chance and we will prove our capability. With your kind help, we believe that we can create a bright future with you together.
  • A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Hannah from Bahamas - 2018.12.28 15:18
    This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Karen from Houston - 2018.05.13 17:00
    Write your message here and send it to us