Specifications

Syringe Size 5,10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
Flow Rate Syringe 5 ml: 0.1-100 ml/hSyringe 10 ml: 0.1-300 ml/hSyringe 20 ml: 0.1-600 ml/h

Syringe 30 ml: 0.1-800 ml/h

Syringe 50/60 ml: 0.1-1500 ml/h

0.1-99.99 mL/h, in 0.01 ml/h increments

100-999.9 ml/h in 0.1 ml/h increments

1000-1500 ml/h in 1 ml/h increments

Flow Rate Accuracy ±2%
VTBI 0.10mL~99999.99mL (Minimum in 0.01 ml/h increments)
Accuracy ±2%
Time 00:00:01~99:59:59(h:m:s)  (Minimum in 1s increments)
Flow Rate  ( Body weight ) 0.01~9999.99 ml/h ;(in 0.01 ml increments)unit: ng/kg/min、ng/kg/h、ug/kg/min、ug/kg/h、mg/kg/min、mg/kg/h、IU/kg/min、IU/kg/h、EU/kg/min、EU/kg/h
Bolus Rate Syringe 5 ml: 50mL/h-100.0 mL/hSyringe 10 ml: 50mL/h-300.0 mL/hSyringe 20 ml: 50mL/h-600.0 mL/h

Syringe 30 ml: 50mL/h-800.0 mL/h

Syringe 50/60 ml: 50mL/h-1500.0 mL/h

50-99.99 mL/h, in 0.01 ml/h increments

100-999.9 ml/h in 0.1 ml/h increments

1000-1500 ml/h in 1 ml/h increments

Accuray: ±2%

Bolus Volume Syringe 5 ml: 0.1mL-5.0 mLSyringe 10 ml: 0.1mL-10.0 mLSyringe 20 ml: 0.1mL-20.0 mL

Syringe 30 ml: 0.1mL-30.0 mL

Syringe 50/60 ml: 0.1mL-50.0 /60.0mL

Accuracy: ±2% or ±0.2mL

Bolus , Purge Syringe 5mL :50mL/h -100.0 mL/hSyringe 10mL:50mL/h -300.0 mL/hSyringe 20mL:50 mL/h -600.0 mL/h

Syringe 30mL:50 mL/h -800.0 mL/h

Syringe 50mL:50 mL/h -1500.0 mL/h

(Minimum in 1mL/h increments)

Accuracy: ±2%

Occlusion Sensitivity 20kPa-130kPa, adjustable (in 10 kPa increments)Accuracy: ±15 kPa or±15%
KVO Rate 1).Automatic KVO On/Off Function2).Automatic KVO is turned off : KVO Rate : 0.1~10.0 mL/h adjustable,(Minimum in 0.1mL/h increments).When flow rate>KVO rate , it runs in KVO rate.

When flow rate <KVO rate , it alarms and runs in flow rate.

3) Automatic KVO is turned on:it adjusts the flow rate automatically.

When flow rate<10mL/h, KVO rate =1mL/h

When flow rate >10 mL/h, KVO=3 mL/h.

Accuracy: ±2%

Basic function Dynamic pressure monitoring, Anti-Bolus, Key Locker, Standby, Historical memory, Drug library.
Alarms Occlusion, syringe drop off, door open, near end , end program, low battery, end battery, motor malfunction, system malfunction, standby alarm, syringe installation error
Infusion Mode Rate mode, Time mode, Body weight, Sequence Mode、Dose Mode、Ramp Up/Down Mode、Micro-Infu Mode
Additional Features Self-checking, System Memory, Wireless (optional), Cascade, Battery Missing Prompt, AC Power Off Prompt.
Air-in-line Detection Ultrasonic detector
Power Supply, AC AC100V~240V 50/60Hz, 35 VA
Battery 14.4 V, 2200mAh ,Lithium, rechargeable
Weight of Battery 210g
Battery Life 10 hours at 5 ml/h
Working Temperature 5℃~40℃
Relative Humidity 15%~80%
Atmospheric Pressure 86KPa~106KPa
Size 290×84×175mm
Weight <2.5 kg
Safety Classification Class ⅠI, type CF. IPX3

5
8
7
9
11
10

FAQ:

Q:what’s the MOQ for this model ?

A: 1 unit.

Q: Is the OEM acceptable ? and what is the MOQ for OEM ?

A: Yes , We can do OEM based on 30 units .

Q: Are you the manufacture of this product.

A: Yes, since 1994

Q: Do you have CE and ISO certificates?

A: Yes . all our products are CE and ISO certified

Q: What is the warranty ?

A: We give two years warranty.

Q: Is this model workable with Docking station?

A: Yes

 

11
13Model KL-6061N
Syringe Size 5, 10, 20, 30, 50/60 mL
Applicable Syringe Compatible with syringe of any standard
VTBI 0.1-99999.99 mL (in 0.01 mL increments)
Infused Volume 0-99999.99 mL (in 0.01 mL increments)
Flow Rate Syringe 5 ml: 0.1-100 ml/h
Syringe 10 ml: 0.1-300 ml/h
Syringe 20 ml: 0.1-600 ml/h
Syringe 30 ml: 0.1-800 ml/h
Syringe 50/60 ml: 0.1-1500 ml/h
0.1-99.99 mL/h in 0.01 ml/h increments
100-999.9 mL/h in 0.1 ml/h increments
1000-1500 mL/h in 1 ml/h increments
Bolus Rate (Manual, Auto) 50 ml/h-1500 ml/h (in 0.01, 0.1, 1 mL increments)
Bolus Volume 0.1-50 mL (in 0.1 mL increments)
Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy ≤1%)
Infusion Mode Rate mode, micro mode, time mode, body weight,
initial dose mode, sequential mode, ramp up/down mode
KVO Rate 0.1-10 mL/h (in 0.1 mL/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery, no battery
AC power off, motor malfunction, system malfunction, standby,
syringe installation error, syringe drop off
Additional Features Automatic power switching, automatic syringe identification, mute key,
purge, bolus, anti-bolus, system memory, key locker,
change flow rate without stopping the pump
Drug Library Available
Occlusion Sensitivity 12 levels (20-130 kPa, in 10 kPa increments)
Occlusion Unit kPa, mmHg, psi, bar
History Log 100,000 events
Alarm Volume 8 levels
Auto. multi-channel relay Available
Power Supply, AC AC100-240V 50/60Hz
Battery DC14.4V, rechargeable
Battery Life 10 hours at 5 ml/h
Working Temperature 5-40℃
Relative Humidity 15-80%
Atmospheric Pressure 860-1060 hpa
Size 290*175*84 mm
Weight 2.5 kg
Waterproof IPX3
Safety Classification Class Ⅱ, type CF