2021 New Style Double Syringe Pump - KL-702 Syringe Pump – KellyMed
2021 New Style Double Syringe Pump - KL-702 Syringe Pump – KellyMed Detail:
FAQ
Q: Do you have CE mark for this product?
A: Yes.
Q: Dual channel syringe pump?
A: Yes, two channels which can be operated separately and simultaneously.
Q: Is the pump open system?
A: Yes, Universal syringe can be used with our Syringe Pump.
Q: It the pump available to have customized syringe?
A: Yes, we have two customized syringes.
Q: Does the pump save last infusion rate and VTBI even when the AC power is switched OFF?
A: Yes, it is memory function.
Specifications
Model | KL-702 |
Syringe Size | 10, 20, 30, 50/60 ml |
Applicable Syringe | Compatible with syringe of any standard |
VTBI | 0.1-10000 ml
<100 ml in 0.1 ml increments ≥100 ml in 1 ml increments |
Flow Rate | Syringe 10 ml: 0.1-420 ml/h
Syringe 20 ml: 0.1-650 ml/h Syringe 30 ml: 0.1-1000 ml/h Syringe 50/60 ml: 0.1-1600 ml/h <100 ml/h in 0.1 ml/h increments ≥100 ml/h in 1 ml/h increments |
Bolus Rate | Syringe 10 ml: 200-420 ml/h
Syringe 20 ml: 300-650 ml/h Syringe 30 ml: 500-1000 ml/h Syringe 50/60 ml: 800-1600 ml/h |
Anti-Bolus | Automatic |
Accuracy | ±2% (mechanical accuracy ≤1%) |
Infusion Mode | Flow rate: ml/min, ml/h
Time-based Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc. |
KVO Rate | 0.1-1 ml/h (in 0.1 ml/h increments) |
Alarms | Occlusion, near empty, end program, low battery, end battery,
AC power off, motor malfunction, system malfunction, standby, pressure sensor error, syringe installation error, syringe drop off |
Additional Features | Real-time infused volume, automatic power switching, automatic syringe
identification, mute key, purge, bolus, anti-bolus, system memory, history log, key locker, separate channel alarm, power saving mode |
Drug Library | Available |
Occlusion Sensitivity | High, medium, low |
History Log | 50000 events |
Wireless Management | Optional |
Power Supply, AC | 110/230 V (optional), 50/60 Hz, 20 VA |
Battery | 9.6±1.6 V, rechargeable |
Battery Life | Power saving mode at 5 ml/h,
10 hours for single channel, 7 hours for double channel |
Working Temperature | 5-40℃ |
Relative Humidity | 20-90% |
Atmospheric Pressure | 860-1060 hpa |
Size | 330*125*225 mm |
Weight | 4.5 kg |
Safety Classification | Class Ⅱ, type CF |
Product detail pictures:
Related Product Guide:
"Sincerity, Innovation, Rigorousness, and Efficiency" would be the persistent conception of our corporation to the long-term to establish collectively with customers for mutual reciprocity and mutual benefit for 2021 New Style Double Syringe Pump - KL-702 Syringe Pump – KellyMed , The product will supply to all over the world, such as: Naples, Vietnam, Turkey, With the development and enlargement of mass clients abroad, now we have set up cooperative relationships with many major brands. We have our own factory and also have many reliable and well-cooperated factories in the field. Adhering to the "quality first, customer first, We are provideing high-quality, low-cost products and first-class service to customers. We sincerely hope to establish business relationship with customers from all over the world on the basis of quality, mutually benefit. We welcome OEM projects and designs.
By Queena from Plymouth - 2018.09.23 18:44
Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
By Eileen from Leicester - 2018.10.01 14:14