head_banner

2021 High quality Syringe Driver - KL-605T Syringe Pump – KellyMed

2021 High quality Syringe Driver - KL-605T Syringe Pump – KellyMed

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

No matter new customer or previous client, We believe in prolonged time period and trustworthy relationship for Intrathecal Infusion Pump, Kangaroo Tube, Iv Pole And Pump, Our organization has been devoting that "customer first" and committed to helping clients expand their small business, so that they become the Big Boss !
2021 High quality Syringe Driver - KL-605T Syringe Pump – KellyMed Detail:

FAQ

Q: Automatic recognition of syringe size and fixation

A: Yes.

Q: Syringe barrel clamp alarm?

A: Yes, it is Syringe Error alarm.

Q: Syringe plunger disengaged alarm?

A: Yes, it is Installation Error alarm.

Q: Automatic anti-bolus?

A: Yes, anti-bolus system to reduce pressure on sudden release of occlusion.

Q: Is it capable of horizontal stacking of more than two pumps?

A: Yes, it is stackable up to 4 pumps or 6 pumps.

 

Specifications

Model KL-605T
Syringe Size 5, 10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 1-1000 ml (in 0.1, 1, 10 ml increments)
Flow Rate Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)

Syringe 10 ml: 0.1-300 ml/h

Syringe 20 ml: 0.1-600 ml/h

Syringe 30 ml: 0.1-800 ml/h

Syringe 50/60 ml: 0.1-1200 ml/h

Bolus Rate Same as flow rate
Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy≤1%)
Infusion Mode Flow rate: ml/min, ml/h

Time-based

Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h etc.

KVO Rate 0.1-1 ml/h (in 0.01 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,

AC power off, motor malfunction, system malfunction, standby,

pressure sensor error, syringe installation error, syringe drop off

Additional Features Real-time infused volume, automatic power switching,

automatic syringe identification, mute key, purge, bolus, anti-bolus,

system memory, history log, key locker

Drug Library Available
Occlusion Sensitivity High, medium, low
Docking Station Stackable up to 4-in-1 or 6-in-1 Docking Station with single power cord
History Log 50000 events
Wireless management Optional
Power Supply, AC 110/230 V, 50/60 Hz, 20 VA
Battery 14.8 V, rechargeable
Battery Life 8 hours at 5 ml/h
Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 700-1060 hpa
Size 245*120*115 mm
Weight 2.5 kg
Safety Classification Class Ⅱ, type BF

Product detail pictures:

2021 High quality Syringe Driver - KL-605T Syringe Pump – KellyMed detail pictures


Related Product Guide:

Our target should be to consolidate and improve the high-quality and repair of current goods, in the meantime regularly produce new solutions to meet unique customers' needs for 2021 High quality Syringe Driver - KL-605T Syringe Pump – KellyMed , The product will supply to all over the world, such as: Maldives, Seychelles, luzern, Only for accomplishing the good-quality product to meet customer's demand, all of our products have been strictly inspected before shipment. We always think about the question on the side of the customers, because you win, we win!
  • This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Colin Hazel from kazan - 2017.06.29 18:55
    It is a very good, very rare business partners, looking forward to the next more perfect cooperation!
    5 Stars By Gwendolyn from Zurich - 2017.12.31 14:53
    Write your message here and send it to us